V

Vermeer Optical Workbench

Building cutaway

Drag to orbit · scroll to zoom
Lens → projection screenScreen → comparator → one eyeNorth wall: lens + separate light window

Comparator eye view

One eye · finite pupil
Click the reflected image to sample paint
Vertical canvas paint

254 × 254 mm projection screen

Delft arrangement and assumptions

This scene follows Tim’s November–December 2017 correspondence: a handmade 1500 mm lens, usually stopped to 84 mm (f/17.8), mounted about 4 m above the ground in the north wall; a movable 10 × 10-inch projection screen; a 2 × 4-inch comparator; and a vertical canvas, usually about 20 cm from the eye. The lens projects onto the screen. The eye views that diffuse screen through the comparator, with no concave mirror in this arrangement. The working model positions and angles the canvas to coincide with the reflected screen plane. Its eye starts 320 mm from the reference image point; Tim’s approximately 200 mm distance is a source reference, not the current model setting.

A separate north-facing window with an adjustable shutter lights the canvas. The flag prevents this light washing out the projection screen. Open the shutter or remove the flag to explore the effect. The apparatus overview uses brighter inspection lighting; it is not a photometric rendering of the dark room.

Estimated: the 4 × 3 × 5 m building, working platform, window and flag dimensions, exact component positions and comparator angles. The platform merely makes the high working level visible; the emails do not describe its construction. The exterior is a simplified canal and building test scene, not a reconstruction of Delft or Vermeer’s painting.

The glass is modelled as a plano-convex lens. Its starting n = 1.52, 10 mm centre thickness and 120 mm full diameter are assumptions, adjustable in the controls. The 1500 mm focal length determines the convex radius for the selected index. Lens orientation can be reversed; the actual Delft orientation and profile are unverified. The original glass prescription, full lens diameter and screen material are unknown. The screen is modelled as a matte diffuser, reflecting 75% of incident light. Screen irradiance is integrated using analytic intersections with the flat and spherical surfaces, Snell refraction, Fresnel losses, a separate entrance aperture stop and cosine weighting. Each pass adds 24 aperture samples; the 512-pixel screen refines up to 1536 samples per pixel on Balanced and 3072 on Fine. Quick uses a 256-pixel screen. The eye then refines across eight pupil samples per pass. Brightness scales with aperture area and projection distance. Window illumination and unflagged spill use illustrative gains; brightness is not calibrated in lux or cd/m². Diffraction, spectral dispersion, glass defects, eye physiology, and multiple reflections are omitted.

The single lens forms an inverted real image. Its appearance in the comparator follows the actual mirror orientation; no corrective texture flip is applied. The focus button numerically solves paraxial focus at the test buildings, 110 m away. Changing screen distance changes optical focus. The canvas follows the geometrically reflected screen plane; its offset slider deliberately separates the planes to reveal parallax. Head movement follows the canvas axes, including depth movement in room coordinates. The screen test grid is a registration diagnostic, replacing the projected scene rather than simulating lens detail.

Source: 14 November 2017 · 7 December 2017. The messages describe a temporary building, without building dimensions or an explicit shipping-container description.